Tellus Data Center

Standby Power

Where: Navanakron, Pathum Thani, Thailand

What: 12 MW of standby power comprising of eight units of diesel generator sets C1675 D5A powered by KTA50 GS8 engine, integrated with PowerCommand® 3.3 Control System and two units of PowerCommand® Digital Master Control (DMC) 1000

Purpose: Provide reliable standby power for Tellus Data Center to ensure uninterrupted critical load during utility outage

Primary Choice Factors:

  • Cummins Power Generation (CPG) has a proven track record of product reliability, offering integrated solutions.
  • Excellent customer and technical support.
  • Vast expertise and experience on data centers

Delivering uninterrupted, superior telecommunications services

In recent years, Thailand’s mobile data service sector has experienced rapid growth, with revenues

estimated to reach more than US$1.5 billion by 2015. At the heart of this exciting industry is Advanced Info Service (AIS), the number one mobile operator in Thailand with a 43 percent market share.

As the country’s leading mobile operator, AIS is committed to deliver uninterrupted service to its customers, even in the event of a utility outage. A subsidiary of AIS, Fax Lite Co. Ltd. owns and operates the Tellus Data Center which houses AIS’ mobile switching facilities. The data center was designed to comply with Tier 3 data center requirements to ensure minimal planned and unplanned downtime.

A complete power solution

Cummins provided 12 MW of reliable standby power for Tellus Data Center.

In order to support the high availability requirements, Fax Lite Co. Ltd needed to deploy reliable standby power that would ensure uninterrupted critical load in the event of an outage. Fax Lite Co. Ltd. considered several vendors based on the following criteria: cost competitiveness, product reliability and excellent customer support.

CPG was selected as the vendor of choice based on its capabilities in designing, integrating and commissioning dependable power systems. AIS purchased 12 units of Cummins generator sets in 2001 for mobile-switching facilities. In 2008, two more generator sets were installed, supplying 2000 kVA of standby power.

For this project, CPG supplied 12 MW of standby power with eight units of diesel-powered generator sets C1675 D5A, integrated with a PowerCommand® 3.3 control system and two units of PowerCommand Digital Master Control (DMC) 1000. Using common communications protocols, integrated microprocessor-based controls are utilised for system control and protection functions to enhance the reliability and performance of the Tellus Data Center.

The PowerCommand DMC 1000 paralleling system provides supervisory and transfer functions such as generator control and management, load management and sequence of operation control.

“The DMC 1000 paralleling system interfaces directly with the PowerCommand generator set controller to optimize system performance and simplify operation management. The two units ensured redundancy in the power system so that at any point in time, 6MVA of power is delivered by four generator sets,” explained

Apiched Bunluenuecharee, Sales and Marketing Manager for Cummins DKSH (Thailand )

The local distributor, Cummins DKSH (Thailand ), further supported Fax Lite with their vast data center expertise throughout the entire implementation process—serving as a single point of contact to help the Thai mobile operator resolve any technical issues quickly.

“Cummins generator sets have proven to be reliable, overcoming a brief utility outage which caused a chiller to shut down. The generator sets kicked in within seven seconds to provide power for the high-speed chiller,” added Apiched.

Continuous innovation for the future

With advanced data center capabilities, AIS is ready to take on the evolving challenges of the telecommunications industry. CPG has provided AIS with the reliable power infrastructure it needs to create and sustain more innovative services in the future.

“Cummins generator sets have proven to be reliable, overcoming a brief utility outage which caused a chiller to shut down. The generator sets kicked in within seven seconds
to provide power for the high-speed chiller.”

Contact Cummins DKSH (Thailand) today to inquire about the Cummins Power Generators that best suited to your business by calling +662-301-7500 or click the button below

ONE STOP FOR CUMMINS SOLUTION IN THAILAND​

we provide full solutions for every need, from Goods: Diesel Engines for all applications, Power Generators covered variety of business type to aftermarket services: components, parts, consumables, repairing, PM, or annual overhaul. We are certified for global standards for our workshop, engineers, and technicians by Cummins. We have our sales team support nationwide plus every need in Laos and Cambodia. We are your power solutions partner that your business can rely on

Diesel Engine

Covering all applications

Power Generator

Serving all needs of back-up power generation from livestock farms to large data centers

Components & Parts

Genuine Components & Parts, Filters to Lubricant Oil ready in one stop

Services

Planned Maintenance, Repair to Overhaul. For all In-shop or On-site requested